    R4C

    segments.  It is designed to be generic, supporting the publication of various types of measurements (energy, power, voltage, etc.) and structures (index, volume, consumption, production).

    This file type contains data for 1 PRM.

    MeterNumber = "PRM/Id_PRM"

    Mapping config format:  R4C_%Nature_De_courbe_Demandee%_%Frequence_Publication%_%Reference_Publication%_%Sens_Mesure%_%Type_Mesure%_%Classe_Temporelle%_%Statut_Point%

    Field                     Description                                      Possible Values
    %Nature_De_courbe_Demandee% Type of curve requested                         Brute, Corrigée
    %Frequence_Publication%   Publication frequency                            Q: Daily
    H: Weekly
    M: Monthly
    %Reference_Publication%   Publication reference                            To be defined
    %Sens_Mesure%             Direction of measurement                         0: Consumption (soutirage)
    1: Injection
    %Type_Mesure%             Type of measurement                              PA: Active Power
    PR: Reactive Power
    %Classe_Temporelle%       Time class                                       See Enedis Energy Community documentation
    %Statut_Point%            Status of the measurement point                  R: Measured
    S: Power outage
    E: Estimated
    C: Corrected

    Example:  R4C_Brute_Q_20240501_0_PA_HP_R