R17
This flow contains readings and indexes for C2, C3, and C4 customers. It is used to monitor detailed consumption data for customers in these segments. This file type can contain data for multiple PRMs.
The file includes several types of measurement data, but only the active energy measurement type is supported in this integration.
MeterNumber = <Identifiant_PRM>
Mapping config format:
R17_Classe_Temporelle_%classeTemporelle%_Classe-%classe%_%statutMesure%_%natureMesure%
Field | Description | Possible Values |
---|---|---|
%classeTemporelle% | Time class used to transmit indexes or measurements | Pointe , HP , HC , HPH , HCH , HPE , HCE , HCDemiSaison , HPDemiSaison , JA , P+HP , HP+HC , P+HP+HC , NHDB , NHDH , PAB , PAH , PM |
%classe% | Indicates whether the data is an index or a measurement | 1 : Index 2 : Consumption |
%statutMesure% | Status of the measurement group | INITIAL , RECTIFICATIF , ANNULE |
%natureMesure% | Type of measurement group | REEL , ESTIME , REGULARISE |
Example:
R17_Classe_Temporelle_Base_Classe-2_INITIAL_REGULARISE