R15
Contains readings and indexes for C5 profiled customers. Used to send monthly readings for all customers within a supplier’s perimeter. Can contain data for multiple PRMs.
MeterNumber = <Identifiant_PRM>
Mapping config format :
R15_Classe_Temporelle_%idClasseTemporelle%_Classe-%classe%_%nature%
Field | Description | Possible Values |
---|---|---|
%idClasseTemporelle% | Time class used for indexes or measurements | HP, HC, HPH, HCH, HPE, HCE, etc. |
%classe% | Indicates index or measurement | 1 : Index 2 : Consumption |
%nature% | Type of measurement | REEL , ESTIME , REGULARISE , AUTO-RELEVE |
Example: R15_Classe_Temporelle_BASE_Classe-2_REEL